16ch CWDM Mux/Demux

Viscore PN# 

VM-CWDM-xx-yy-a-b-c-d

Customer  PN#

TBD

Product Description

CWDM Mux/Demux Module

CWDM Mux/Demux Module

Performance Specifications

Parameter

Specification

Operating Wavelength (nm)

1290-1620

Operating Center Wavelength (nm)

1310,1370,1390,1410,1430,1450,1470,

1490,1510,1530,1550,1570,1590,1610

1310 Channel Pass-band (@-0.5dB bandwidth) (nm)

Center-wavelength +/-20

CWDM Channels Pass-band (@-0.5dB bandwidth) (nm)

Center-wavelength +/-6.5

Insertion Loss (1550 Channel Trunk) (dB)

1.2 (Typ)

1.5 (Max)

Insertion Loss (1610 Channel Trunk) (dB)

1.5 (Typ)

2.0 (Max)

Insertion Loss (1590 Channel Trunk) (dB)

3.0 (Typ)

4.0 (Max)

Insertion Loss (1570 Channel Trunk) (dB)

2.8 (Typ)

4.0 (Max)

Insertion Loss (1530 Channel Trunk) (dB)

2.5 (Typ)

3.5 (Max)

Insertion Loss (1510 Channel Trunk) (dB)

2.3 (Typ)

3.5 (Max)

Insertion Loss (1490 Channel Trunk) (dB)

1.8 (Typ)

2.5 (Max)

Insertion Loss (1470 Channel Trunk) (dB)

2.0 (Typ)

3.0 (Max)

Insertion Loss (1450 Channel Trunk) (dB)

1.8 (Typ)

2.5 (Max)

Insertion Loss (1430 Channel Trunk) (dB)

2.8 (Typ)

4.0 (Max)

Insertion Loss (1410 Channel Trunk) (dB)

2.5 (Typ)

4.0 (Max)

Insertion Loss (1390 Channel Trunk) (dB)

2.5 (Typ)

3.5 (Max)

Insertion Loss (1370 Channel Trunk) (dB)

2.0 (Typ)

3.0 (Max)

Insertion Loss (1310 Channel Trunk) (dB)

1.5 (Typ)

2.0 (Max)

Channel Ripple (dB)

0.3 (Typ)

0.5 (Max)

Isolation Adjacent  Channel  (dB)

35 (Typ)

30 (Min)

Isolation Non-adjacent Channel  (dB)

45 (Typ)

40 (Min)

Polarization Dependent Loss (dB)

< 0.20 

Return Loss (dB)

>45  

Fiber Type (used in internal routing)

SMF-28e

Connector Type (trunk)

SC-APC

Connector Type (other channels)

LC-APC

Max Power Handling (mW)

500

Operating Temperature (°C)

0 ~ +70

Storage Temperature (°C)

-40 ~ +85

Dimensions

1 slot LGX

Note: Insertion Loss Including Connectors