Viscore invest in the hybrid passive technologies to deliver world class performance. The hybrid passive parts for EDFA modules save the space and cost for the highly integrated EDFA design.
Performance Specification
|
Parameters |
Unit |
Specifications |
|
Signal Channel Operation Wavelength Range |
nm |
1525--1565 |
|
Pump Channel Operation Wavelength Range |
nm |
970 - 990 |
|
Signal Channel Isolation within Pump Wavelength (@23°C,all SOP) |
dB |
≥ 30 |
|
Insertion Loss of 980nm WL at 5% tap port |
dB |
≥ 26 |
|
Pump Channel Isolation (within Signal Wavelength @23°C,all SOP) |
dB |
≥ 12 |
|
Pump Channel Insertion Loss (within band and 0—70°C,all SOP) |
dB |
≤ 0.7 |
|
Signal Channel Insertion Loss (within band and 0—70°C,all SOP) |
dB |
≤1.4 |
|
Nominal Tap Ratio Insertion Loss (within band and 0—70°C,all SOP) |
dB |
12.2—14.5(5%) |
|
Wavelength Dependent Loss at 95% Tap port |
dB |
≤0.15 |
|
Wavelength Dependent Loss at 5% Tap port |
dB |
≤0.3 |
|
Return Loss(all ports) |
dB |
≥50 |
|
Directivity (T®R and R®T) |
dB |
≥50 |
|
PDL |
dB |
≤ 0.1 |
|
PMD |
ps/nm |
≤ 0.1 |
|
Fiber Type |
SMF-28 at Tap & Transmission, Hi-1060 at Pump & Common |
|
|
Fiber Length |
m |
1.0 +0.1/-0.0 |
|
Connectors |
None |
|
|
Package Dimension |
mm |
5.5 ± 0.10 (f) ´ 38 max (L) |
|
Power Handling |
mw |
³ 300 |
|
Operation Temperature |
°C |
0 ~ +70 |
|
Storage Temperature |
°C |
-40 ~ +85 |
Ordering Information
|
HTW- |
|
|
|
|
|
|
|
Tap Ratio |
WDM WL |
Fiber Type |
Fiber Length |
In/Out Connector |
|
|
05=5% |
95F=980/1550nm Forward 45F=1480/1550nm Froward |
1=Bare Fiber |
1=1 Meter |
0=None |